21 CFR 1271.210: Supplies and reagents

Establishments must verify supplies and reagents meet specifications preventing communicable disease risk before use, use sterile reagents where appropriate, validate in-house reagent production, and keep receipt, verification, and lot-use records.

Part 1271, Human Cells, Tissues, and Cellular and Tissue-Based Products · Subpart D, Current Good Tissue Practice

Recent 483s citing 1271.210

See all 483s citing 1271.210

The regulation text

§ 1271.210 Supplies and reagents.

(a)Verification. You must not use supplies and reagents until they have been verified to meet specifications designed to prevent circumstances that increase the risk of the introduction, transmission, or spread of communicable diseases. Verification may be accomplished by the establishment that uses the supply or reagent, or by the vendor of the supply or reagent.

(b)Reagents. Reagents used in processing and preservation of HCT/Ps must be sterile, where appropriate.

(c)In-house reagents. You must validate and/or verify the processes used for production of in-house reagents.

(d)Records. You must maintain the following records pertaining to supplies and reagents:

(1)Records of the receipt of each supply or reagent, including the type, quantity, manufacturer, lot number, date of receipt, and expiration date;

(2)Records of the verification of each supply or reagent, including test results or, in the case of vendor verification, a certificate of analysis from the vendor; and

(3)Records of the lot of supply or reagent used in the manufacture of each HCT/P.

Questions

What does 21 CFR 1271.210 require?

Establishments must verify supplies and reagents meet specifications preventing communicable disease risk before use, use sterile reagents where appropriate, validate in-house reagent production, and keep receipt, verification, and lot-use records.

Which sections are cited alongside 1271.210?

In the same 483s, investigators most often also cite 1271.170 (Personnel), 1271.200 (Equipment), 1271.230 (Process validation), 1271.250 (Labeling controls).