21 CFR 211.84: Testing and approval or rejection of components, drug product containers, and closures
Requires manufacturers to quarantine each lot of components, containers, and closures until representative samples are properly collected, tested for identity and specification conformity, and released by the quality control unit.
Part 211, Current Good Manufacturing Practice for Finished Pharmaceuticals · Subpart E, Control of Components and Drug Product Containers and Closures
20%
of drug-manufacturing 483s since 2023 cite this section at least once
How FDA words it
The opening lines investigators use most when they cite 211.84, from the 483s we hold.
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and…Most used
Establishment of the reliability of the component supplier's report of analyses is deficient in that the test results are not appropriately validated at appropriate intervals.211.84(d)
The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.211.84(d)
Cited over time
483s citing 211.84, by yearMost citations in 2023. Bars are relative to the busiest year. *2026 to date.
Years shown: 2017 to 2026. The busiest year was 2023.
Recent 483s citing 211.84
- Greenwich Rx · Tomball, TexasUse of ingredients not intended for phaimaceutical use in sterile diug production… Sep 9, 2026
- OPS International Inc. dba Olympia Pharmaceuticals · Orlando, FloridaComponent testing is deficient in that each component is not tested for conformity… Sep 3, 2026
- Houston Rx LLC · Houston, TexasUse of ingredients not intended for pharmaceutical use in sterile drug production… Aug 28, 2026
- Apollo Care, LLC · Columbia, MissouriEach component is not tested for conformity with all appropriate written… Jul 28, 2026
- Cascade Specialty Pharmacy, LLC · Poulsbo, WashingtonSpecific identification tests are not conducted on components that have been… Jul 17, 2026
The regulation text
§ 211.84 Testing and approval or rejection of components, drug product containers, and closures.
(a)Each lot of components, drug product containers, and closures shall be withheld from use until the lot has been sampled, tested, or examined, as appropriate, and released for use by the quality control unit.
(b)Representative samples of each shipment of each lot shall be collected for testing or examination. The number of containers to be sampled, and the amount of material to be taken from each container, shall be based upon appropriate criteria such as statistical criteria for component variability, confidence levels, and degree of precision desired, the past quality history of the supplier, and the quantity needed for analysis and reserve where required by § 211.170.
(c)Samples shall be collected in accordance with the following procedures:
(1)The containers of components selected shall be cleaned when necessary in a manner to prevent introduction of contaminants into the component.
(2)The containers shall be opened, sampled, and resealed in a manner designed to prevent contamination of their contents and contamination of other components, drug product containers, or closures.
(3)Sterile equipment and aseptic sampling techniques shall be used when necessary.
(4)If it is necessary to sample a component from the top, middle, and bottom of its container, such sample subdivisions shall not be composited for testing.
(5)Sample containers shall be identified so that the following information can be determined: name of the material sampled, the lot number, the container from which the sample was taken, the date on which the sample was taken, and the name of the person who collected the sample.
(6)Containers from which samples have been taken shall be marked to show that samples have been removed from them.
(d)Samples shall be examined and tested as follows:
(1)At least one test shall be conducted to verify the identity of each component of a drug product. Specific identity tests, if they exist, shall be used.
(2)Each component shall be tested for conformity with all appropriate written specifications for purity, strength, and quality. In lieu of such testing by the manufacturer, a report of analysis may be accepted from the supplier of a component, provided that at least one specific identity test is conducted on such component by the manufacturer, and provided that the manufacturer establishes the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
(3)Containers and closures shall be tested for conformity with all appropriate written specifications. In lieu of such testing by the manufacturer, a certificate of testing may be accepted from the supplier, provided that at least a visual identification is conducted on such containers/closures by the manufacturer and provided that the manufacturer establishes the reliability of the supplier's test results through appropriate validation of the supplier's test results at appropriate intervals.
(4)When appropriate, components shall be microscopically examined.
(5)Each lot of a component, drug product container, or closure that is liable to contamination with filth, insect infestation, or other extraneous adulterant shall be examined against established specifications for such contamination.
(6)Each lot of a component, drug product container, or closure with potential for microbiological contamination that is objectionable in view of its intended use shall be subjected to microbiological tests before use.
(e)Any lot of components, drug product containers, or closures that meets the appropriate written specifications of identity, strength, quality, and purity and related tests under paragraph (d) of this section may be approved and released for use. Any lot of such material that does not meet such specifications shall be rejected.
[43 FR 45077, Sept. 29, 1978, as amended at 63 FR 14356, Mar. 25, 1998; 73 FR 51932, Sept. 8, 2008]
Questions
What does 21 CFR 211.84 require?
Requires manufacturers to quarantine each lot of components, containers, and closures until representative samples are properly collected, tested for identity and specification conformity, and released by the quality control unit.
How often is 211.84 cited in Form 483s?
It appears in about 20% of the drug-manufacturing 483s we hold from 2023 onward, which makes it one of the ten most-cited sections in those 483s.
How do FDA investigators word a 211.84 observation?
The most common opening is: “Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and…”
Which sections are cited alongside 211.84?
In the same 483s, investigators most often also cite 211.22 (Responsibilities of quality control unit), 211.192 (Production record review), 211.67 (Equipment cleaning and maintenance), 211.160 (General requirements).