Tayca Corporation
FDA inspection history in Okayama, Japan, 2017 to 2023
- 2
- Form 483s
Every document, by year
- Form 483
2017: one Form 483; 2023: one Form 483.
The story so far
Built from the dates and citations on the documents themselves.
- 2017One Form 483, at Okayama, Japan.
- 2017The longest 483 on file: 9 observations over 5 pages at Okayama, Japan.
- 2023One Form 483, at Okayama, Japan.
Cited most
Across all Tayca observations on file
- 21 CFR 211.160General requirements4
- 21 CFR 211.192Production record review3
- 21 CFR 211.68Automatic, mechanical, and electronic equipment2
- 21 CFR 211.166Stability testing1
- 21 CFR 211.194Laboratory records1
The complete Tayca file.
All 2 documents as original PDFs, in one order. For supplier audits, diligence and inspection prep.
The price of the documents, added to your cart together
Sites
Okayama, Japan
Two Form 483s · 2017 to 2023 · 9 observations
Latest: Form 483, Aug 25, 2023 →
Documents
2 on file, newest first| Date | Document | Location | Observations | Price |
|---|---|---|---|---|
| 2023-08-25 | 483 Form 483 | Okayama, Japan | — | $99 |
| 2017-12-15 | 483 Form 483 | Okayama, Japan | 9 | $99 |
Investigators on these documents
FEI number 3002777902 · most recent document Aug 25, 2023
About Tayca Corporation
How many FDA Form 483s has Tayca Corporation received?
FDA Intel has 2 Form 483s on file for Tayca Corporation; the most recent is dated Aug 25, 2023.
When was Tayca Corporation last inspected by FDA?
The most recent FDA inspection document on file for Tayca Corporation is a Form 483 dated Aug 25, 2023, for the site in Okayama, Japan.
What did FDA cite at Tayca Corporation?
The regulations cited most in the observations on file for Tayca Corporation are 21 CFR 211.160 (General requirements), 4 times; 21 CFR 211.192 (Production record review), 3 times; 21 CFR 211.68 (Automatic, mechanical, and electronic equipment), 2 times.