Sanofi Pasteur Inc.

Form 483 issued October 26, 2018 · Swiftwater, Pennsylvania

Inspection
Oct 22 – Oct 26, 2018
Observations
2
Pages
1
FEI number
2518760

In short: On October 26, 2018, FDA issued a Form 483 with 2 observations to Sanofi Pasteur Inc. in Swiftwater, Pennsylvania (FEI 2518760) after an inspection that ran Oct 22 – Oct 26, 2018. The investigators were Christian Lynch, Dino Feigelstock and Solomon Yimam. Most observations concern production; the most-cited regulation is 21 CFR 211.100 (written procedures; deviations).

At a glance

Observations span 1 system, led by production.

Production1
Other1

Most cited: 21 CFR 211.100 (1×)

What FDA observed

Preview: the opening words of each observation

Dashed: section inferred by FDA Intel and checked against the regulation text

  1. 01

    Procedures regarding YF-VAX production…

  2. 02

    (b) (4) cycle failures associated with the Line (b) (4) are not…

The full 483

Plus the full detail behind each one, exactly as FDA wrote it.

Get the full 483

This inspection in context

Questions about this 483

What did FDA find at Sanofi Pasteur Inc.?

FDA listed 2 observations on this Form 483, mostly about production. The most-cited regulation is 21 CFR 211.100 (written procedures; deviations). The opening words of each observation are shown on this page.

Who inspected Sanofi Pasteur Inc.?

Christian Lynch, Dino Feigelstock and Solomon Yimam are named on this Form 483, for the inspection of Oct 22 – Oct 26, 2018. Each investigator has a profile showing what they cite most.

When was Sanofi Pasteur Inc. inspected by FDA?

The inspection ran Oct 22 – Oct 26, 2018, and the Form 483 is dated October 26, 2018.

How do I get the full Form 483 for Sanofi Pasteur Inc.?

Download the original PDF from FDA Intel for $99, with no subscription. Your first Form 483 or letter is on us. You also get an invoice PDF with the order.