Jost Chemical Co.

Form 483 issued January 21, 2022 · Saint Louis, Missouri

Inspection
Jan 10 – Jan 21, 2022
Observations
6
Pages
8
FEI number
3001239108

In short: On January 21, 2022, FDA issued a Form 483 with 6 observations to Jost Chemical Co. in Saint Louis, Missouri (FEI 3001239108) after an inspection that ran Jan 10 – Jan 21, 2022. Most observations concern quality system and facilities & equipment; the most-cited regulation is 21 CFR 211.192 (production record review).

At a glance

Quality system and facilities & equipment account for 4 of 6 observations.

Quality system2
Facilities & equipment2
Production1
Laboratory controls1

What FDA observed

Preview: the opening words of each observation

Dashed: section inferred by FDA Intel and checked against the regulation text

  1. 01

    Written records of investigations are not established and followed for investigating critical deviations or the failure…

  2. 02

    Quality related complaints are not always investigated and, if appropriate, corrective actions…

  3. 03

    Equipment is not cleaned at appropriate intervals to build-up…

  4. 04

    Computer systems used in production and quality control laboratories do not have sufficient controls to prevent…

2 more observations

Plus the full detail behind each one, exactly as FDA wrote it.

Get the full 483

This inspection in context

Questions about this 483

What did FDA find at Jost Chemical Co.?

FDA listed 6 observations on this Form 483, mostly about quality system, facilities & equipment and production. The most-cited regulation is 21 CFR 211.192 (production record review). The opening words of each observation are shown on this page.

When was Jost Chemical Co. inspected by FDA?

The inspection ran Jan 10 – Jan 21, 2022, and the Form 483 is dated January 21, 2022.

How do I get the full Form 483 for Jost Chemical Co.?

Download the original PDF from FDA Intel for $99, with no subscription. Your first Form 483 or letter is on us. You also get an invoice PDF with the order.

$99Get it free